FLUKE 381 амперклещ
- үнэ: 2,700,000 төг
What Once Took Two People, Now Takes One
Now one technician can do jobs that would otherwise require two people. Clamp the Fluke 381 around a conductor, remove the display and walk across the room to operate controls or remove protective equipment, all while watching real-time readings.
The iFlex® Flexible Current Probe (included) expands the measurement range to 2500 A AC while providing increased display flexibility. With a cord that runs 6 feet, you can finally measure those tight spaces, awkward sized conductors and disorganized wires.
Key features
- – Wireless technology allows the display to be carried up to 30 ft. away from the point of measurement for added flexibility without interference with measurement accuracy
- – The removable magnetic display can be conveniently mounted where it is easily seen
- – iFlex® Flexible Current Probe expands the measurement range to 2500 A AC
- – CAT IV 600 V, CAT III 1000 V
- – Integrated low pass filter and state-of-the-art signal processing allows for use in noisy electrical environments while providing stable readings
- – Proprietary inrush measurement technology to filter out noise and capture motor starting current exactly as the circuit protection sees it
- – Ergonomic design fits in your hand and can be used while wearing protective equipment
- – Radio transmitter automatically sets the correct measurement range so you do not need to change the switch positions while taking a measurement
- – Three-year warranty
- – Soft carrying case
Safety Conformance
IEC/EN 61010-1:2001, 1000V CAT III, 600V CAT IV
Specifications: Fluke 381 Remote Display True RMS AC/DC Clamp Meter with iFlex®
Electrical Specifications | ||||
AC Current via Jaw | ||||
Range | 999.9 A | |||
Resolution | 0.1 A | |||
Accuracy | 2% ± 5 digits (10-100 Hz) 5% ± 5 digits (100-500 Hz) |
|||
Crest Factor (50/60 Hz) | 3 @ 500 A 2.5 @ 600 A 1.42 @ 1000 A Add 2% for C.F. > 2 |
|||
AC Current via Flexible Current Probe | ||||
Range | 999.9 A / 2500 A (45 Hz – 500 Hz) | |||
Resolution | 0.1 A / 1 A | |||
Accuracy | 3% ± 5 digits | |||
Crest Factor (50/60 Hz) | 3.0 at 1100 A 2.5 at 1400 A 1.42 at 2500 A Add 2% for C.F. > 2 |
|||
Position Sensitivity | ||||
Distance from Optimum | ||||
i2500-10 Flex | i2500-18 Flex | Error | ||
A | 0.5 in (12.7 mm) | 1.4 in (35.6 mm) | ±0.5% | |
B | 0.8 in (20.3 mm) | 2.0 in (50.8 mm) | ±1.0% | |
C | 1.4 in (35.6 mm) | 2.5 in (63.5 mm) | ±2.0% | |
Measurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field, and within operating temperature range. | ||||
DC Current | ||||
Range | 999.9 A | |||
Resolution | 0.1 A | |||
Accuracy | 2% ± 5 digits | |||
AC Voltage | ||||
Range | 600 V /1000 V | |||
Resolution | 0.1 V / 1 V | |||
Accuracy | 1.5% ± 5 digits (20 – 500 Hz) | |||
DC Voltage | ||||
Range | 600.0 V /1000 V | |||
Resolution | 0.1 V / 1 V | |||
Accuracy | 1% ± 5 digits | |||
Frequency – Via Jaw | ||||
Range | 5.0 – 500.0 Hz | |||
Resolution | 0.1 Hz | |||
Accuracy | 0.5% ± 5 digits | |||
Trigger Level | 5 – 10 Hz, ≥ 10 A 10 – 100 Hz, ≥ 5 A 100 – 500 Hz, ≥ 10 A |
|||
Frequency via Flexible Current Probe | ||||
Range | 5.0 to 500.0 Hz | |||
Resolution | 0.1 Hz | |||
Accuracy | 0.5% ± 5 digits | |||
Trigger Level | 5 to 20 Hz, ≥ 25 A 20 to 100 Hz, ≥ 20 A 100 to 500 Hz, ≥ 25 A |
|||
Resistance | ||||
Range | 600 Ω/6 kΩ/60 kΩ | |||
Resolution | 0.1 Ω/1 Ω/10 Ω | |||
Accuracy | 1% ± 5 digits | |||
Mechanical Specifications | ||||
Size (L x W x H) | 277 x 88 x 43 mm (55 mm for remote unit) | |||
Weight | 350 g | |||
Jaw Opening | 34 mm | |||
Flexible Current Probe Diameter | 7.5 mm | |||
Flexible Current Probe Cable Length (head to electronics connector) |
1.8 m | |||
Environmental Specifications | ||||
Operating Temperature | -10°C to +50°C | |||
Storage Temperature | -40°C to +60°C | |||
Operating Humidity | Non condensing (< 10°C) ≤ 90% RH (at 10°C to 30°C) ≤ 75% RH (at 30°C to 40°C) ≤ 45% RH (at 40°C to 50°C) (Without Condensation) |
|||
Operating Altitude | 2,000 meters | |||
Storage Altitude | 12,000 meters | |||
EMI, RFI, EMC, RF | EN 61326-1:2006, EN 61326-2-2:2006 ETSI EN 300 328 V1.7.1:2006 ETSI EN 300 489 V1.8.1:2008 FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249 FCCID: T68-F381 RSS-210 IC: 6627A-F381 |
|||
Temperature Coefficients | Add 0.1 x specified accuracy for each degree C above 28°C or below 18°C | |||
Wireless Frequency | 2.4 GHz ISM Band 10 meter range | |||
Safety Compliance | ANSI/ISA S82.02.01:2004 CAN/CSA-C22.2 No. 61010-1-04 IEC/EN 61010-1:2001 to 1000V CAT III, 600V CAT IV. |
|||
Double Insulation Clearance | Per IEC 61010-2-032 | |||
Double Insulation Creepage | Per IEC 61010-1 | |||
Agency Approvals |
Санал болгох бараа
Үйлдвэрлэгч
Хэмжих хэрэгсэл
- Мультиметр
- Амперклещ
- Эсэргүүцэл хэмжигч
- LCR метр
- Осциллограф
- Спектр анализатор
- Дохионы үүсгүүр
- Тэжээлийн блок
- Цахилгаан хэмжигч, хайгч
- Термометр
- Орчны тестер
- Сүлжээний тестер
- Тахометр
- Зай хэмжигч
- Бусад хэмжих хэрэгсэл
- Дагалдах хэрэгсэл
Гагнуурын хэрэгсэл
- Нихром гагнуурын алх
- Керамик гагнуурын алх
- Тохируулгатай гагнуурын алх
- Үлээдэг гагнуурын алх
- Урьдчилан халаагч
- Утасгүй гагнуурын алх
- Тугалга сорогч
- Тугалга, давирхай
- Эд анги
- Хошуу
- Халаагч
- Гар
- Туслах хэрэгсэл
- Халуун цавууны буу
- Хамгаалалтын хэрэгсэл
Гар багаж
- Халив
- Нарийн халив
- Том халив
- Тусгай халив
- Цахилгаан халив
- Халив цуглуулга
- Тусгай түлхүүр, торцов
- Бахь
- Бахь
- Нугас, махир хошуут бахь
- Таслагч бахь
- Хямсаа
- Кабел үзүүрлэгч
- Төгсгөвч хавчигч
- Сүлжээний бахь
- Цагираг түгжээ авагч
- Хайч, хутга
- Өрөм, хөрөө, хуурай
- 1000В гар багаж
- Туслах хэрэгсэл
Томруулдаг шил
- Микроскоп
- Томруулдаг шил
- Суурин томруулдаг шил
Багажны цуглуулга
- Багажны цүнх
- Электроникийн багаж
- Цахилгааны багаж
- Сүлжээний багаж
Лавлах утас: 99198321
Хаяг : Улаанбаатар хот, Чингэлтэй дүүрэг, Компьютер ланд, 3-н давхар, 12 тоот