Мультиметр FLUKE 77IV

  • үнэ: 1,700,000 төг

- Large display

- Backlight for work in dim areas

- Min / Max to record signal fluctuations

- Ergonomic overmolded housing with integrated probe holders

- Free your hands with the optional TPAK magnetic hanger

- Auto and Manual ranging

- Meets Measurement Category 1000 V CAT III and Category IV 600 V safety standards

Specifications
Voltage DC Range 6.000 V – 1000 V
Best accuracy ±(0.3% + 1)
Best resolution 0.1 mV
Voltage AC Range 600.0 mV – 1000V
Best accuracy ±(2.0% + 2)
Best resolution 1.0 mV
Amps AC Range 60.00 mA – 10 A
Best accuracy 2.5% + 2
Best resolution 0.01 mA
Amps DC Range 60.00 mA – 10A
Best accuracy 1.5% + 2
Best resolution 0.01 mA
Resistance Range 600.0 Ω – 50 MΩ
Best accuracy ±(0.5% + 1)
Best resolution 0.1 Ω
Capacitance Range 1nF – 9,999 μF
Best accuracy ±(1.2% + 2)
Best resolution 1 nF
Frequency Range 99.99Hz – 99.99kHz
Best accuracy ±(0.1% + 1)
Best resolution 0.01 Hz
Safety ANSI / ISA S82.02.01, CSA C22.2–1010.1, IEC 61010 to 1000 V Measurement Category III, 600 V Measurement Category IV
Certifications CSA, TÜV (EN61010), Π, (N10140)

 

General Specifications
Maximum voltage between any terminal and earth ground 1000 V
Surge protection 8 kV peak per IEC 61010
Ω Fuse for mA inputs 440 mA, 1000 V FAST Fuse
Ω Fuse for A inputs 11 A, 1000 V FAST Fuse
Display Digital 6000 counts, updates 4/sec
Bar graph 33 segments, updates 32/sec
Frequency 10,000 counts
Capacitance 1,000 counts
Altitude Operating 2,000 meters
Storage 12,000 meters
Temperature Operating -10°C to + 50°C
Storage -40°C to + 60°C
Temperature coefficient 0.1 x (specified accuracy / °C (< 18°C or > 28°C)
Electromagnetic compatibility
(EN 61326–1:1997)
In an RF field of 3 V/M, accuracy = specified accuracy except in temperature:
specified accuracy ±5°C (9°F)
Relative humidity
(maximum non-condensing)
90% to 35°C
75% to 40°C
45% to 50°C
Battery life 400 hours typical (alkaline)
Size (H x W x L) 4.3 x 9 x 18.5 cm
Weight 420 g

FLUKE 77IV multimeter